Maintence
1 Grouting should determine the water pressure in time to determine the grouting pressure.
2 The grouting machine should be set on the working surface for excellent grouting during grouting.
3 In the process of grouting, the water leakage condition of the water point and surrounding joint cracks should be investigated at any time. If the appearance of slurry, slurry leakage, etc., the technical measures such as external plugging, intermittent grouting and thick slurry should be adopted for timely disposal.
4 If the intermittent grouting method is used during grouting, the intermittent moment should be slightly shorter than the gelation time of the slurry.
5 Injecting potassium permanganate color water into the grouting hole before grouting to investigate the water pressure experiment and record the briquette point adjacent to the grouting hole and use the cotton wool to timely seal with the grouting pump.

Common fault treatment
Phenomenon 1 No starching, cylinder barrel is burning, hands can not touch cylinder barrel for a long time
1) Check whether there is air leakage place at the slurry injection pipeline and joint
2) Pull rod, Strike tightly seal cover clockwise at the packing place and guarantee it doesn’t leak slurry or air.
3) Check slurry injection and drainage group valve, use special spanner or pipe vice to separate group valve, clean valve seat and valve ball, and wipe off foreign body. Please exchange in case of damage.
Phenomenon 2 Cylinder doesn’t work.
1) Check whether silencer is clogged and clean the silencer
2) Remove calm valve. Exchange the calm valve in case that push rod can not reset with the spring force. Check whether pneumatic control valve is normal in case that push rod can reset with the spring force.