Fix the grouting pump, grouting hose, etc. during construction, and the grouting hose is in a slack state;
After grouting, it is necessary to clean the grouting pump and the grouting hose in time, and the switches are in the stop and break position, and the power is cut off in time.
Do not put your hand into the mixer, storage hopper or put the hard object into the mixer and conveying screw at any time.
After the filling slurry is completed, the grouting hose should be cleaned in time, the grouting pump should be cleaned, equipment inspection and maintenance and other finishing work should be carried out.
After the filling slurry is completed, add water to the hopper and press the [grouting] button to operate the equipment.
When the water flowing out of the grouting hose is clean water, it indicates that there is no cement mortar in the equipment to stop.
When cleaning the equipment casing from clean water, avoid flushing the electric control box with water.
Remove the grouting hose and store the coil.
Remove the booster stator, use a wrench to unscrew the booster worm, and store the booster worm oil.
Pull out the conveying screw and store the oil at the end.
Pay attenti