Contact information:
Summer
Mobile/Wechat/Whatsapp: +86 13571973823
Email: summer@ztmineequipment.com
How to use the Grouting Mixer Pump:
When spraying on a dry, water-absorbent, or thickly reinforced wall, the nozzle should be 10-15cm away from the wall and 90 from the wall. The spray moving speed should be slower and the compressed air pressure should be lower. When spraying a wall with damp conditions, poor water absorption, or two-strength reinforcement, the nozzle is 15-30cm away from the wall and at a 900 angle to the wall. The sprayer can move faster and the compressed air volume should be slightly larger. The surface is large, the ash layer is thin, and the mortar is not easy to flow. The inner wall usually survives twice. When spraying for the second time, the spray should be a little farther away from the wall.


Application of Concrete grouting pump:
Grouting Mixer Pump is mainly used in the construction, spraying cement mortar on the internal wall, and spraying heat insulating material, fireproof materials on the external wall.
Specification:
Capacity 3m³/H
Motor power 7.5KW/3KW
Diameter of sand ≦5mm
Diameter of feeding pipe 32MM
Vertical spraying distance 20M
Horizontal spraying distance 30M
Hopper volume 220L
Dimension 1900*700*1150
water:cement:sand 1:01:03
Voltage 380V(three-phase)
Function:mixing ,grouting, spraying(cab be customized)


Precautions Grouting Mixer Pump:
Before spraying, the sprayed area should be infiltrated with water; when spraying, the nozzle should be as vertical as possible to the sprayed surface (the distance can be adjusted according to the spraying effect) layered and evenly sprayed, and coordinated with the leveling process. If the wall is too dry or the time after spraying is too long, it will seriously affect the leveling effect, and the process must be changed.
Fill the hopper evenly without interruption. When the conveying screw rotates, it is strictly forbidden to stir in the hopper with a stick to prevent injury.
Once the shotcrete delivery pipe is blocked, switch the switch to the manual position, only turn on the compressor, remove the quick connector in front of the pump head, and then block the spray head downwards, and the wind pressure generates reverse pressure to blow the remaining slurry out of the delivery pipe. After installing the quick connector, it starts to work normally.
When spraying hands, wear safety helmets, protective glasses, protective clothing, and other protective equipment.

Contact information:
Summer
Mobile/Wechat/Whatsapp: +86 13571973823
Email: summer@ztmineequipment.com
Hot Tags: Grouting Mixer Pump, manufacturers, suppliers, factory, wholesale, buy, cheap, low price